Accessories

Image Part Number Description / PDF Quantity Rfq
72-157-9

72-157-9

NTE Electronics, Inc.

WHITE INSULATOR FOR 72-148/149/1

496

72-157-4

72-157-4

NTE Electronics, Inc.

YELLOW INSULATOR 72-148/149/153/

181

72-028

72-028

NTE Electronics, Inc.

SAFETY PLUG ADAPTER BLACK

168

72-099R

72-099R

NTE Electronics, Inc.

GLOVE STYLE INSULATOR

57

72-131-6

72-131-6

NTE Electronics, Inc.

BLUE INSULATOR FOR 72-129/130

769

72-033

72-033

NTE Electronics, Inc.

4MM SHUTTER PLUG BLACK

90

72-036

72-036

NTE Electronics, Inc.

4MM IN LINE SOCKET RED

177

72-176-6

72-176-6

NTE Electronics, Inc.

BLUE INSULATOR FOR 72-173/173PS/

796

72-119-2

72-119-2

NTE Electronics, Inc.

RED INSULATOR FOR 72-116/117/118

422

72-046

72-046

NTE Electronics, Inc.

4MM PANEL SOCKET RED

14

72-119-4

72-119-4

NTE Electronics, Inc.

YEL INSULATOR FOR 72-116/117/118

591

72-166-5

72-166-5

NTE Electronics, Inc.

GRN INSULATOR FOR 72-167/168

755

72-143-9

72-143-9

NTE Electronics, Inc.

WHT INSULATOR FOR 72-136/137

740

72-042

72-042

NTE Electronics, Inc.

4MM PANEL SOCKET YELLOW

436

72-135-2

72-135-2

NTE Electronics, Inc.

RED PVC INSULATOR FOR 72-133/134

1442

72-029

72-029

NTE Electronics, Inc.

SAFETY PLUG ADAPTER RED

170

72-127-6

72-127-6

NTE Electronics, Inc.

BLUE INSULATOR FOR 72-124/126

792

72-039

72-039

NTE Electronics, Inc.

4MM PANEL SOCKET GREEN

701

72-182-0

72-182-0

NTE Electronics, Inc.

BANANA COUPLER INSUL BLK

552

72-143-0

72-143-0

NTE Electronics, Inc.

BLK INSULATOR FOR 72-136/137

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email